ГОСТ IEC 60050-551-2022. Межгосударственный стандарт. Международный электротехнический словарь. Часть 551. Силовая электроника
Алфавитный указатель эквивалентов терминов
на английском языке
A | |
a.c. |
|
AC conversion factor .................................................................................... | 551-17-13 |
a.c. converter ............................................................................................... | 551-12-17 |
a.c. filter ....................................................................................................... | 551-14-19 |
a.c. voltage converter .................................................................................... | 551-12-25 |
direct a.c. converter ...................................................................................... | 551-12-18 |
electronic AC power controller ..................................................................... | 551-13-04 |
(electronic) a.c. (power) conversion .............................................................. | 551-11-08 |
electronic AC (power) switch ....................................................................... | 551-13-02 |
indirect a.c. converter ................................................................................... | 551-12-19 |
indirect current link a.c. converter ................................................................. | 551-12-20 |
indirect voltage link a.c. converter ................................................................. | 551-12-21 |
a.c./d.c. |
|
a.c./d.c. converter ........................................................................................ | 551-12-02 |
current stiff a.c./d.c. converter ...................................................................... | 551-12-04 |
direct a.c./d.c. converter ............................................................................... | 551-12-06 |
(electronic) a.c./d.c. (power) conversion ....................................................... | 551-12-05 |
indirect a.c./d.c. converter ............................................................................ | 551-12-06 |
voltage stiff a.c./d.c. converter ...................................................................... | 551-12-03 |
active |
|
active power filter ......................................................................................... | 551-12-16 |
advance |
|
trigger advance angle .................................................................................... | 551-16-34 |
angle |
|
angle of overlap ............................................................................................ | 551-16-05 |
circuit angle .................................................................................................. | 551-17-02 |
current delay angle ........................................................................................ | 551-16-32 |
inherent delay angle ....................................................................................... | 551-16-35 |
trigger advance angle .................................................................................... | 551-16-34 |
trigger delay angle ......................................................................................... | 551-16-33 |
antiparallel |
|
pair of antiparallel arms ................................................................................. | 551-15-04 |
area |
|
crossover area .............................................................................................. | 551-19-09 |
arm(s) |
|
auxiliary arm ................................................................................................. | 551-15-05 |
breakdown (of an electronic valve device or an arm) ...................................... | 551-16-66 |
by-pass arm .................................................................................................. | 551-15-06 |
free-wheeling arm ......................................................................................... | 551-15-07 |
pair of antiparallel arms ................................................................................. | 551-15-04 |
pair of arms .................................................................................................. | 551-15-03 |
principal arm ................................................................................................. | 551-15-02 |
regenerative arm ............................................................................................ | 551-15-09 |
turn-off arm ................................................................................................... | 551-15-08 |
(valve) arm .................................................................................................... | 551-15-01 |
assembly |
|
valve device assembly ................................................................................... | 551-14-13 |
asymmetrical |
|
asymmetrical phase control ............................................................................ | 551-16-25 |
auto-sequential |
|
auto-sequential commutation .......................................................................... | 551-16-18 |
automatic |
|
automatic switching off ................................................................................... | 551-18-08 |
automatic switching on ................................................................................... | 551-18-07 |
auxiliary |
|
auxiliary arm .................................................................................................. | 551-15-05 |
B | |
band |
|
tolerance band ............................................................................................... | 551-19-07 |
basic |
|
basic converter connection ............................................................................. | 551-15-11 |
blocking |
|
circuit reverse blocking interval ...................................................................... | 551-16-51 |
forward blocking state ................................................................................... | 551-16-41 |
non-reverse blocking valve device .................................................................. | 551-14-06 |
reverse blocking state .................................................................................... | 551-16-42 |
reverse blocking valve device ......................................................................... | 551-14-05 |
valve device blocking ..................................................................................... | 551-16-69 |
boost |
|
boost and buck connection ............................................................................ | 551-15-21 |
boost converter ............................................................................................. | 551-12-32 |
breakdown |
|
breakdown (of an electronic valve device or an arm) ...................................... | 551-16-66 |
forward breakdown ....................................................................................... | 551-16-67 |
reverse breakdown ........................................................................................ | 551-16-68 |
breakthrough |
|
breakthrough ................................................................................................. | 551-16-60 |
bridge |
|
bridge connection .......................................................................................... | 551-15-14 |
buck |
|
boost and buck connection ............................................................................ | 551-15-21 |
buck converter .............................................................................................. | 551-12-33 |
by-pass |
|
by-pass arm ................................................................................................... | 551-15-06 |
C | |
capacitor |
|
capacitor commutation ................................................................................... | 551-16-17 |
commutation capacitor ................................................................................... | 551-14-15 |
characteristic |
|
characteristic (curve) (of a converter) ............................................................. | 551-18-01 |
composite characteristic ................................................................................. | 551-18-10 |
forced characteristic (of a line commutated converter) .................................... | 551-18-03 |
jumping characteristic .................................................................................... | 551-18-09 |
natural characteristic (of a line commutated converter) .................................... | 551-18-02 |
stabilized current characteristic ....................................................................... | 551-18-06 |
stabilized output characteristic ........................................................................ | 551-18-04 |
stabilized voltage characteristic ....................................................................... | 551-18-05 |
chopper |
|
d.c. chopper .................................................................................................. | 551-12-28 |
circuit |
|
circuit angle ................................................................................................... | 551-17-02 |
circuit crest working off-state voltage ............................................................. | 551-16-53 |
circuit crest working reverse voltage ............................................................... | 551-16-56 |
circuit non-repetitive peak off-state voltage .................................................... | 551-16-55 |
circuit non-repetitive peak reverse voltage ...................................................... | 551-16-58 |
circuit off-state interval ................................................................................... | 551-16-52 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
circuit repetitive peak reverse voltage ............................................................. | 551-16-57 |
circuit reverse blocking interval ...................................................................... | 551-16-51 |
commutation circuit ........................................................................................ | 551-16-03 |
snubber (circuit) ............................................................................................. | 551-14-17 |
coefficient |
|
total harmonic distortion coefficient ................................................................ | 551-17-06 |
commutated |
|
forced characteristic (of a line commutated converter) ..................................... | 551-18-03 |
natural characteristic (of a line commutated converter) ..................................... | 551-18-02 |
commutating |
|
commutating group ........................................................................................ | 551-16-08 |
commutating voltage ...................................................................................... | 551-16-02 |
multiple connection (of commutating groups) .................................................. | 551-15-20 |
commutation |
|
auto-sequential commutation .......................................................................... | 551-16-18 |
capacitor commutation ................................................................................... | 551-16-17 |
commutation ................................................................................................. | 551-16-01 |
commutation capacitor ................................................................................... | 551-14-15 |
commutation circuit ........................................................................................ | 551-16-03 |
commutation failure ......................................................................................... | 551-16-59 |
commutation inductance ................................................................................. | 551-16-07 |
commutation interval ...................................................................................... | 551-16-04 |
commutation notch ......................................................................................... | 551-16-06 |
commutation number ...................................................................................... | 551-17-03 |
commutation reactor ...................................................................................... | 551-14-14 |
direct commutation ......................................................................................... | 551-16-09 |
external commutation ...................................................................................... | 551-16-11 |
indirect commutation ....................................................................................... | 551-16-10 |
line commutation ............................................................................................ | 551-16-12 |
load commutation .......................................................................................... | 551-16-13 |
machine commutation ..................................................................................... | 551-16-14 |
self-commutation ............................................................................................ | 551-16-15 |
valve device commutation ............................................................................... | 551-16-16 |
composite |
|
composite characteristic ................................................................................. | 551-18-10 |
conducting |
|
conducting direction (of an electronic valve device or of a valve arm) .............. | 551-16-43 |
conducting state ............................................................................................. | 551-16-40 |
non-conducting direction (of an electronic valve device or of a valve arm) ........ | 551-16-44 |
conduction |
|
conduction interval (of a valve arm) ................................................................ | 551-16-48 |
conduction ratio ............................................................................................. | 551-16-50 |
conduction through ........................................................................................ | 551-16-64 |
connected |
|
multi-connected converter .............................................................................. | 551-12-41 |
connection |
|
basic converter connection ............................................................................. | 551-15-11 |
boost and buck connection ............................................................................. | 551-15-21 |
bridge connection .......................................................................................... | 551-15-14 |
converter connection ...................................................................................... | 551-15-10 |
double-way connection (of a converter) ......................................................... | 551-15-13 |
fully controllable connection ........................................................................... | 551-15-17 |
half-controllable connection ........................................................................... | 551-15-19 |
multiple connection (of commutating groups) .................................................. | 551-15-20 |
non-controllable connection ............................................................................ | 551-15-16 |
non-uniform connection .................................................................................. | 551-15-18 |
single-way connection (of a converter) ........................................................... | 551-15-12 |
stage (of a series connection) ......................................................................... | 551-15-22 |
uniform connection ........................................................................................ | 551-15-15 |
constant |
|
constant current power supply ........................................................................ | 551-19-05 |
constant voltage to constant current crossover ................................................ | 551-19-08 |
constant voltage to constant current crossover ................................................ | 551-19-08 |
constant voltage or constant |
|
current power supply ..................................................................................... | 551-19-06 |
constant voltage or constant current power supply ........................................... | 551-19-06 |
constant voltage power supply ....................................................................... | 551-19-04 |
content |
|
harmonic content ........................................................................................... | 551-17-04 |
continuous |
|
continuous flow (of direct current) .................................................................. | 551-16-71 |
control |
|
asymmetrical phase control ............................................................................. | 551-16-25 |
(electronic) (power) resistance control ............................................................ | 551-11-04 |
multicycle control ........................................................................................... | 551-16-31 |
multicycle control factor ................................................................................. | 551-16-37 |
phase control ................................................................................................. | 551-16-23 |
phase control factor ....................................................................................... | 551-16-36 |
pulse control .................................................................................................. | 551-16-27 |
pulse control factor ........................................................................................ | 551-16-38 |
pulse duration control ..................................................................................... | 551-16-28 |
pulse frequency control .................................................................................. | 551-16-29 |
pulse width modulation control ....................................................................... | 551-16-30 |
PWM control (abbreviation) .......................................................................... | 551-16-30 |
sequential phase control ................................................................................. | 551-16-26 |
symmetrical phase control .............................................................................. | 551-16-24 |
controllable |
|
controllable valve device ................................................................................ | 551-14-03 |
fully controllable connection ........................................................................... | 551-15-17 |
half-controllable connection ............................................................................ | 551-15-19 |
non-controllable connection ............................................................................ | 551-15-16 |
non-controllable valve device ......................................................................... | 551-14-04 |
controlled |
|
controlled conventional no-load direct voltage ................................................. | 551-17-18 |
controlled ideal no-load direct voltage ............................................................ | 551-17-16 |
controller |
|
electronic AC power controller ...................................................................... | 551-13-04 |
conventional |
|
controlled conventional no-load direct voltage ................................................. | 551-17-18 |
conventional no-load direct voltage ................................................................. | 551-17-17 |
conversion |
|
AC conversion factor ..................................................................................... | 551-17-13 |
conversion factor (in general) .......................................................................... | 551-17-10 |
DC conversion factor ..................................................................................... | 551-17-14 |
direct (power) conversion ............................................................................... | 551-11-10 |
(electronic) a.c. (power) conversion ............................................................... | 551-11-08 |
(electronic) a.c./d.c. (power) conversion ......................................................... | 551-11-05 |
(electronic) d.c. (power) conversion ............................................................... | 551-11-09 |
(electronic) (power) conversion ...................................................................... | 551-11-02 |
indirect (power) conversion ............................................................................ | 551-11-11 |
converter |
|
a.c. converter ................................................................................................. | 551-12-17 |
a.c. voltage converter ..................................................................................... | 551-12-25 |
a.c./d.c. converter .......................................................................................... | 551-12-02 |
basic converter connection ............................................................................. | 551-15-11 |
boost converter .............................................................................................. | 551-12-32 |
buck converter .............................................................................................. | 551-12-33 |
characteristic (curve) (of a converter) ............................................................. | 551-18-01 |
converter connection ...................................................................................... | 551-15-10 |
converter section of a double converter .......................................................... | 551-12-40 |
converter section of a double converter .......................................................... | 551-12-40 |
current stiff a.c./d.c. converter ........................................................................ | 551-12-04 |
d.c. converter ................................................................................................ | 551-12-27 |
direct a.c. converter ....................................................................................... | 551-12-18 |
direct a.c./d.c. converter ................................................................................ | 551-12-05 |
direct d.c. converter ...................................................................................... | 551-12-28 |
double converter ............................................................................................ | 551-12-39 |
double-way connection (of a converter) ......................................................... | 551-15-13 |
(electronic) (power) converter ........................................................................ | 551-12-01 |
flyback converter ........................................................................................... | 551-12-31 |
forced characteristic (of a line commutated converter) ..................................... | 551-18-03 |
forward converter .......................................................................................... | 551-12-30 |
four-quadrant converter ................................................................................. | 551-12-36 |
frequency converter ....................................................................................... | 551-12-22 |
indirect a.c. converter .................................................................................... | 551-12-19 |
indirect a.c./d.c. converter ............................................................................. | 551-12-06 |
indirect current link a.c. converter ................................................................... | 551-12-20 |
indirect d.c. converter .................................................................................... | 551-12-29 |
indirect voltage link a.c. converter ................................................................... | 551-12-21 |
multi-connected converter .............................................................................. | 551-12-41 |
natural characteristic (of a line commutated converter) ..................................... | 551-18-02 |
phase converter ............................................................................................. | 551-12-24 |
one-quadrant converter .................................................................................. | 551-12-34 |
quadrant converter, one ................................................................................. | 551-12-34 |
two-quadrant converter .................................................................................. | 551-12-35 |
reactive power converter ................................................................................ | 551-12-15 |
resonant converter ......................................................................................... | 551-12-26 |
reversible converter ....................................................................................... | 551-12-37 |
semiconductor converter ................................................................................ | 551-12-42 |
single converter .............................................................................................. | 551-12-38 |
single-way connection (of a converter) ............................................................ | 551-15-12 |
step-down converter ...................................................................................... | 551-12-33 |
step-up converter ........................................................................................... | 551-12-32 |
transfer factor (of a d.c. converter) ................................................................. | 551-16-39 |
voltage stiff a.c./d.c. converter ........................................................................ | 551-12-03 |
convertor |
|
(electronic) (power) convertor ....................................................................... | 551-12-01 |
crest |
|
circuit crest working off-state voltage .............................................................. | 551-16-53 |
circuit crest working reverse voltage ............................................................... | 551-16-56 |
crossover |
|
constant voltage to constant current crossover ................................................ | 551-19-08 |
crossover area ............................................................................................... | 551-19-09 |
crossover point .............................................................................................. | 551-19-10 |
current |
|
constant current power supply ........................................................................ | 551-19-05 |
constant voltage to constant current crossover ................................................. | 551-19-08 |
constant voltage or constant current power supply ........................................... | 551-19-06 |
continuous flow (of direct current) .................................................................. | 551-16-71 |
current delay angle ......................................................................................... | 551-16-32 |
current fed inverter ......................................................................................... | 551-12-12 |
current stiff a.c./d.c. converter ........................................................................ | 551-12-04 |
indirect current link a.c. converter ................................................................... | 551-12-20 |
intermittent flow (of direct current) .................................................................. | 551-16-70 |
stabilized current characteristic ....................................................................... | 551-18-06 |
transition current ............................................................................................. | 551-17-20 |
curve |
|
characteristic (curve) (of a converter) ............................................................. | 551-18-01 |
cycloconverter ............................................................................................. |
|
cycloconverter ............................................................................................... | 551-12-23 |
D | |
d.c. |
|
d.c. chopper ................................................................................................... | 551-12-28 |
DC conversion factor ..................................................................................... | 551-17-14 |
d.c. converter ................................................................................................ | 551-12-27 |
d.c. filter ........................................................................................................ | 551-14-18 |
DC form factor .............................................................................................. | 551-17-28 |
DC power ..................................................................................................... | 551-17-09 |
d.c. ripple factor ............................................................................................ | 551-17-29 |
direct d.c. converter ....................................................................................... | 551-12-28 |
(electronic) d.c. (power) conversion ............................................................... | 551-11-09 |
electronic DC (power) switch ......................................................................... | 551-13-03 |
indirect d.c. converter .................................................................................... | 551-12-29 |
ripple voltage (on the d.c. side) ....................................................................... | 551-17-27 |
transfer factor (of a d.c. converter) ................................................................. | 551-16-39 |
delay |
|
current delay angle ......................................................................................... | 551-16-32 |
inherent delay angle ........................................................................................ | 551-16-35 |
trigger delay angle .......................................................................................... | 551-16-33 |
device |
|
breakdown (of an electronic valve device or an arm) ....................................... | 551-16-66 |
controllable valve device ................................................................................. | 551-14-03 |
electronic device ............................................................................................ | 551-14-01 |
electronic valve device .................................................................................... | 551-14-02 |
gas-filled valve device .................................................................................... | 551-14-11 |
high vacuum valve device ................................................................................ | 551-14-10 |
ionic valve device ........................................................................................... | 551-14-11 |
latching valve device ....................................................................................... | 551-14-07 |
non-controllable valve device .......................................................................... | 551-14-04 |
non-reverse blocking valve device ................................................................... | 551-14-06 |
reverse blocking valve device ......................................................................... | 551-14-05 |
semiconductor valve device ............................................................................ | 551-14-09 |
switched valve device ..................................................................................... | 551-14-08 |
threshold voltage (of an electronic valve device) .............................................. | 551-17-26 |
valve device assembly .................................................................................... | 551-14-13 |
valve device blocking ..................................................................................... | 551-16-69 |
valve device commutation ............................................................................... | 551-16-16 |
valve device quenching ................................................................................... | 551-16-20 |
valve device stack .......................................................................................... | 551-14-12 |
diode |
|
rectifier diode ................................................................................................. | 551-14-04 |
direct |
|
continuous flow (of direct current) .................................................................. | 551-16-71 |
controlled conventional no-load direct voltage ................................................. | 551-17-18 |
controlled ideal no-load direct voltage ............................................................ | 551-17-16 |
conventional no-load direct voltage ................................................................ | 551-17-17 |
direct a.c. converter ....................................................................................... | 551-12-18 |
direct a.c./d.c. converter ................................................................................ | 551-12-05 |
direct commutation ........................................................................................ | 551-16-09 |
direct d.c. converter ....................................................................................... | 551-12-28 |
direct inverter ................................................................................................. | 551-12-13 |
direct (power) conversion .............................................................................. | 551-11-10 |
direct rectifier ................................................................................................. | 551-12-08 |
direct voltage regulation .................................................................................. | 551-17-21 |
ideal no-load direct voltage ............................................................................ | 551-17-15 |
inductive direct voltage regulation ................................................................... | 551-17-25 |
inherent direct voltage regulation ..................................................................... | 551-17-22 |
intermittent flow (of direct current) .................................................................. | 551-16-70 |
real no-load direct voltage .............................................................................. | 551-17-19 |
resistive direct voltage regulation ..................................................................... | 551-17-24 |
total direct voltage regulation .......................................................................... | 551-17-23 |
direction |
|
conducting direction (of an electronic valve device or of a valve arm) ............... | 551-16-43 |
non-conducting direction (of an electronic valve device or of a valve arm) ......... | 551-16-44 |
distortion |
|
total harmonic distortion coefficient ................................................................. | 551-17-06 |
double |
|
converter section of a double converter .......................................................... | 551-12-40 |
double converter ............................................................................................ | 551-12-39 |
double-way connection (of a converter) .......................................................... | 551-15-13 |
duration |
|
pulse duration control ..................................................................................... | 551-16-28 |
E | |
electronic(s) |
|
breakdown (of an electronic valve device or an arm) ...................................... | 551-16-66 |
electronic AC power controller ...................................................................... | 551-13-04 |
(electronic) a.c. (power) conversion ................................................................ | 551-11-08 |
electronic AC (power) switch ......................................................................... | 551-13-02 |
(electronic) a.c./d.c. (power) conversion ......................................................... | 551-11-05 |
(electronic) d.c. (power) conversion ............................................................... | 551-11-09 |
electronic DC (power) switch ......................................................................... | 551-13-03 |
electronic device ............................................................................................. | 551-14-01 |
(electronic) (power) conversion ...................................................................... | 551-11-02 |
(electronic) (power) converter ........................................................................ | 551-12-01 |
(electronic) (power) convertor ........................................................................ | 551-12-01 |
electronic power filter ..................................................................................... | 551-12-16 |
(electronic) (power) inversion ......................................................................... | 551-11-07 |
(electronic) (power) rectification ..................................................................... | 551-11-06 |
(electronic) (power) resistance control ............................................................ | 551-11-04 |
electronic (power) switch ............................................................................... | 551-13-01 |
electronic (power) switching ........................................................................... | 551-11-03 |
electronic valve device ................................................................................... | 551-14-02 |
power electronics ........................................................................................... | 551-11-01 |
threshold voltage (of an electronic valve device) .............................................. | 551-17-26 |
elementary |
|
elementary frequency ..................................................................................... | 551-16-47 |
elementary period .......................................................................................... | 551-16-46 |
external |
|
external commutation ...................................................................................... | 551-16-11 |
external quenching .......................................................................................... | 551-16-21 |
F | |
factor |
|
AC conversion factor ..................................................................................... | 551-17-13 |
conversion factor (in general) .......................................................................... | 551-17-10 |
DC conversion factor ..................................................................................... | 551-17-14 |
DC form factor .............................................................................................. | 551-17-28 |
d.c. ripple factor ............................................................................................. | 551-17-29 |
fundamental factor ......................................................................................... | 551-17-07 |
inversion factor .............................................................................................. | 551-17-12 |
multicycle control factor ................................................................................. | 551-16-37 |
phase control factor ....................................................................................... | 551-16-36 |
pulse control factor ........................................................................................ | 551-16-38 |
rectification factor .......................................................................................... | 551-17-11 |
(total) harmonic factor .................................................................................... | 551-17-05 |
transfer factor (of a d.c. converter) ................................................................. | 551-16-39 |
failure |
|
commutation failure ........................................................................................ | 551-16-59 |
firing failure .................................................................................................... | 551-16-65 |
false |
|
false firing ....................................................................................................... | 551-16-63 |
filled |
|
gas-filled valve device .................................................................................... | 551-14-11 |
filter |
|
a.c. filter ........................................................................................................ | 551-14-19 |
active power filter .......................................................................................... | 551-12-16 |
d.c. filter ........................................................................................................ | 551-14-18 |
electronic power filter ..................................................................................... | 551-12-16 |
firing |
|
false firing ....................................................................................................... | 551-16-63 |
firing .............................................................................................................. | 551-16-62 |
firing failure .................................................................................................... | 551-16-65 |
flow |
|
continuous flow (of direct current) .................................................................. | 551-16-71 |
intermittent flow (of direct current) .................................................................. | 551-16-70 |
flyback |
|
flyback converter ........................................................................................... | 551-12-31 |
forced |
|
forced characteristic (of a line commutated converter) ..................................... | 551-18-03 |
form |
|
DC form factor .............................................................................................. | 551-17-28 |
forward |
|
forward blocking state .................................................................................... | 551-16-41 |
forward breakdown ........................................................................................ | 551-16-67 |
forward converter .......................................................................................... | 551-12-30 |
four-quadrant |
|
four-quadrant converter .................................................................................. | 551-12-36 |
free-wheeling |
|
free-wheeling arm ........................................................................................... | 551-15-07 |
frequency |
|
elementary frequency ...................................................................................... | 551-16-47 |
frequency converter ........................................................................................ | 551-12-22 |
pulse frequency control ................................................................................... | 551-16-29 |
fundamental |
|
fundamental factor .......................................................................................... | 551-17-07 |
fundamental power ......................................................................................... | 551-17-08 |
G | |
gas |
|
gas-filled valve device .................................................................................... | 551-14-11 |
group(s) |
|
commutating group ......................................................................................... | 551-16-08 |
multiple connection (of commutating groups) ................................................... | 551-15-20 |
H | |
half |
|
half-controllable connection ............................................................................ | 551-15-19 |
harmonic |
|
harmonic content ............................................................................................ | 551-17-04 |
total harmonic distortion coefficient ................................................................. | 551-17-06 |
(total) harmonic factor .................................................................................... | 551-17-05 |
hold-off |
|
hold-off interval .............................................................................................. | 551-16-45 |
I | |
ideal |
|
controlled ideal no-load direct voltage ............................................................. | 551-17-16 |
ideal no-load direct voltage ............................................................................. | 551-17-15 |
idle |
|
idle interval (of a valve arm) ............................................................................ | 551-16-49 |
indirect |
|
indirect a.c. converter ..................................................................................... | 551-12-19 |
indirect a.c./d.c. converter .............................................................................. | 551-12-06 |
indirect commutation ...................................................................................... | 551-16-10 |
indirect current link a.c. converter ................................................................... | 551-12-20 |
indirect d.c. converter ..................................................................................... | 551-12-29 |
indirect inverter .............................................................................................. | 551-12-14 |
indirect (power) conversion ............................................................................ | 551-11-11 |
indirect rectifier .............................................................................................. | 551-12-09 |
indirect voltage link a.c. converter ................................................................... | 551-12-21 |
inductance |
|
commutation inductance ................................................................................. | 551-16-07 |
inductive |
|
inductive direct voltage regulation ................................................................... | 551-17-25 |
influence |
|
influence quantity ............................................................................................ | 551-19-01 |
inherent |
|
inherent delay angle ........................................................................................ | 551-16-35 |
inherent direct voltage regulation ..................................................................... | 551-17-22 |
intermittent |
|
intermittent flow (of direct current) .................................................................. | 551-16-70 |
interphase |
|
interphase transformer .................................................................................... | 551-14-16 |
interval |
|
circuit off-state interval ................................................................................... | 551-16-52 |
circuit reverse blocking interval ....................................................................... | 551-16-51 |
commutation interval ...................................................................................... | 551-16-04 |
conduction interval (of a valve arm) ................................................................. | 551-16-48 |
hold-off interval .............................................................................................. | 551-16-45 |
idle interval (of a valve arm) ............................................................................ | 551-16-49 |
inversion |
|
(electronic) (power) inversion ......................................................................... | 551-11-07 |
Inversion factor .............................................................................................. | 551-17-12 |
inverter |
|
current fed inverter ......................................................................................... | 551-12-12 |
direct inverter ................................................................................................ | 551-12-13 |
indirect inverter .............................................................................................. | 551-12-14 |
inverter .......................................................................................................... | 551-12-10 |
voltage fed inverter ......................................................................................... | 551-12-11 |
invertor |
|
invertor .......................................................................................................... | 551-12-10 |
ionic |
|
ionic valve device ........................................................................................... | 551-14-11 |
J | |
jumping |
|
jumping characteristic ..................................................................................... | 551-18-09 |
L | |
latching |
|
latching valve device ....................................................................................... | 551-14-07 |
line |
|
forced characteristic (of a line commutated converter) ..................................... | 551-18-03 |
line commutation ............................................................................................. | 551-16-12 |
natural characteristic (of a line commutated onverter) ....................................... | 551-18-02 |
link |
|
indirect current link a.c. converter ................................................................... | 551-12-20 |
indirect voltage link a.c. converter ................................................................... | 551-12-21 |
load |
|
controlled conventional no-load direct voltage ................................................. | 551-17-18 |
controlled ideal no-load direct voltage ............................................................ | 551-17-16 |
conventional no-load direct voltage ................................................................. | 551-17-17 |
ideal no-load direct voltage ............................................................................ | 551-17-15 |
load commutation ........................................................................................... | 551-16-13 |
real no-load direct voltage .............................................................................. | 551-17-19 |
M | |
machine |
|
machine commutation ..................................................................................... | 551-16-14 |
modulation |
|
pulse width modulation control ........................................................................ | 551-16-30 |
multi-connected |
|
multi-connected converter .............................................................................. | 551-12-41 |
multicycle |
|
multicycle control ........................................................................................... | 551-16-31 |
multicycle control factor ................................................................................. | 551-16-37 |
multiple |
|
multiple connection (of commutating groups) ................................................... | 551-15-20 |
N | |
natural |
|
natural characteristic (of a line commutated converter) ..................................... | 551-18-02 |
notch |
|
commutation notch ......................................................................................... | 551-16-06 |
number |
|
commutation number ...................................................................................... | 551-17-03 |
pulse number ................................................................................................. | 551-17-01 |
O | |
off |
|
automatic switching off ................................................................................... | 551-18-08 |
circuit crest working off state voltage .............................................................. | 551-16-53 |
circuit non-repetitive peak off-state voltage ..................................................... | 551-16-55 |
circuit off-state interval ................................................................................... | 551-16-52 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
hold-off interval .............................................................................................. | 551-16-45 |
off state ......................................................................................................... | 551-16-41 |
on |
|
automatic switching on .................................................................................... | 551-18-07 |
on state .......................................................................................................... | 551-16-40 |
one-quadrant |
|
one-quadrant converter .................................................................................. | 551-12-34 |
operation |
|
parallel operation (of stabilized power supplies) ............................................... | 551-19-11 |
slave operation ............................................................................................... | 551-19-12 |
output |
|
stabilized output characteristic ........................................................................ | 551-18-04 |
overlap |
|
angle of overlap ............................................................................................. | 551-16-05 |
P | |
pair |
|
pair of antiparallel arms ................................................................................... | 551-15-04 |
pair of arms ................................................................................................... | 551-15-03 |
parallel |
|
parallel operation (of stabilized power supplies) ............................................... | 551-19-11 |
peak |
|
circuit non-repetitive peak off-state voltage ..................................................... | 551-16-55 |
circuit non-repetitive peak reverse voltage ....................................................... | 551-16-58 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
circuit repetitive peak reverse voltage ............................................................. | 551-16-57 |
period |
|
elementary period .......................................................................................... | 551-16-46 |
phase |
|
asymmetrical phase control ............................................................................. | 551-16-25 |
phase control ................................................................................................. | 551-16-23 |
phase control factor ....................................................................................... | 551-16-36 |
phase converter .............................................................................................. | 551-12-24 |
sequential phase control ................................................................................. | 551-16-26 |
symmetrical phase control ............................................................................... | 551-16-24 |
point |
|
crossover point .............................................................................................. | 551-19-10 |
power |
|
active power filter .......................................................................................... | 551-12-16 |
constant current power supply ........................................................................ | 551-19-05 |
constant voltage or constant current power supply ........................................... | 551-19-06 |
constant voltage power supply ........................................................................ | 551-19-04 |
DC power ..................................................................................................... | 551-17-09 |
direct (power) conversion .............................................................................. | 551-11-10 |
electronic AC power controller ....................................................................... | 551-13-04 |
(electronic) a.c. (power) conversion ................................................................ | 551-11-08 |
electronic AC (power) switch ......................................................................... | 551-13-02 |
(electronic) (power) conversion ...................................................................... | 551-11-02 |
(electronic) (power) converter ........................................................................ | 551-12-01 |
(electronic) (power) convertor ........................................................................ | 551-12-01 |
electronic power filter ..................................................................................... | 551-12-16 |
(electronic) (power) inversion ......................................................................... | 551-11-07 |
(electronic) (power) rectification ..................................................................... | 551-11-06 |
(electronic) a.c./d.c. (power) conversion ......................................................... | 551-11-05 |
(electronic) d.c. (power) conversion ............................................................... | 551-11-09 |
(electronic) (power) resistance control ............................................................ | 551-11-04 |
electronic (power) switch ............................................................................... | 551-13-01 |
electronic (power) switching ........................................................................... | 551-11-03 |
fundamental power ......................................................................................... | 551-17-08 |
indirect (power) conversion ............................................................................ | 551-11-11 |
indirect (power) conversion parallel operation (of stabilized power supplies) .... | 551-19-11 |
power electronics ........................................................................................... | 551-11-01 |
reactive power converter ................................................................................ | 551-12-15 |
stabilized power supply .................................................................................. | 551-19-03 |
principal |
|
principal arm .................................................................................................. | 551-15-02 |
pulse |
|
pulse control .................................................................................................. | 551-16-27 |
pulse control factor ......................................................................................... | 551-16-38 |
pulse duration control ..................................................................................... | 551-16-28 |
pulse frequency control ................................................................................... | 551-16-29 |
pulse number .................................................................................................. | 551-17-01 |
pulse width modulation control ....................................................................... | 551-16-30 |
PWM |
|
PWM control (abbreviation) .......................................................................... | 551-16-30 |
Q | |
quadrant |
|
four-quadrant converter .................................................................................. | 551-12-36 |
one-quadrant converter .................................................................................. | 551-12-34 |
two-quadrant converter .................................................................................. | 551-12-35 |
quantity |
|
influence quantity ............................................................................................ | 551-19-01 |
quenching |
|
external quenching .......................................................................................... | 551-16-21 |
quenching ..................................................................................................... | 551-16-19 |
quenching voltage ........................................................................................... | 551-16-22 |
valve device quenching ................................................................................... | 551-16-20 |
R | |
ratio |
|
conduction ratio ............................................................................................. | 551-16-50 |
reactive |
|
reactive power converter ................................................................................ | 551-12-15 |
reactor |
|
commutation reactor ...................................................................................... | 551-14-14 |
real |
|
real no-load direct voltage .............................................................................. | 551-17-19 |
rectification |
|
(electronic) (power) rectification ..................................................................... | 551-11-06 |
rectification factor ........................................................................................... | 551-17-11 |
rectifier |
|
direct rectifier ................................................................................................. | 551-12-08 |
indirect rectifier .............................................................................................. | 551-12-09 |
rectifier .......................................................................................................... | 551-12-07 |
rectifier diode ................................................................................................. | 551-14-04 |
regenerative |
|
regenerative arm ............................................................................................. | 551-15-09 |
regulation |
|
direct voltage regulation .................................................................................. | 551-17-21 |
inductive direct voltage regulation ................................................................... | 551-17-25 |
inherent direct voltage regulation ..................................................................... | 551-17-22 |
resistive direct voltage regulation ..................................................................... | 551-17-24 |
total direct voltage regulation .......................................................................... | 551-17-23 |
repetitive |
|
circuit non-repetitive peak off-state voltage ..................................................... | 551-16-55 |
circuit non-repetitive peak reverse voltage ...................................................... | 551-16-58 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
circuit repetitive peak reverse voltage ............................................................. | 551-16-57 |
resistance |
|
(electronic) (power) resistance control ............................................................ | 551-11-04 |
resistive |
|
resistive direct voltage regulation ..................................................................... | 551-17-24 |
resonant |
|
resonant converter ......................................................................................... | 551-12-26 |
reverse |
|
circuit crest working reverse voltage ............................................................... | 551-16-56 |
circuit non-repetitive peak reverse voltage ...................................................... | 551-16-58 |
circuit repetitive peak reverse voltage .............................................................. | 551-16-57 |
circuit reverse blocking interval ....................................................................... | 551-16-51 |
non-reverse blocking valve device .................................................................. | 551-14-06 |
reverse blocking state ..................................................................................... | 551-16-42 |
reverse blocking valve device ......................................................................... | 551-14-05 |
reverse breakdown ........................................................................................ | 551-16-68 |
reversible |
|
reversible converter ........................................................................................ | 551-12-37 |
ripple |
|
d.c. ripple factor ............................................................................................. | 551-17-29 |
ripple voltage (on the DC side) ....................................................................... | 551-17-27 |
S | |
section |
|
converter section of a double converter ........................................................... | 551-12-40 |
self |
|
self-commutation ............................................................................................ | 551-16-15 |
semiconductor |
|
semiconductor converter ................................................................................. | 551-12-42 |
semiconductor switch ..................................................................................... | 551-13-05 |
semiconductor valve device ............................................................................ | 551-14-09 |
sequential |
|
auto-sequential commutation ........................................................................... | 551-16-18 |
sequential phase control .................................................................................. | 551-16-26 |
series |
|
stage (of a series connection) .......................................................................... | 551-15-22 |
single |
|
single converter .............................................................................................. | 551-12-38 |
single-way connection (of a converter) ............................................................ | 551-15-12 |
slave |
|
slave operation ............................................................................................... | 551-19-12 |
snubber |
|
snubber (circuit) ............................................................................................. | 551-14-17 |
stabilization |
|
stabilization .................................................................................................... | 551-19-02 |
stabilized |
|
parallel operation (of stabilized power supplies) .............................................. | 551-19-11 |
stabilized current characteristic ....................................................................... | 551-18-06 |
stabilized output characteristic ......................................................................... | 551-18-04 |
stabilized power supply .................................................................................. | 551-19-03 |
stabilized voltage characteristic ....................................................................... | 551-18-05 |
stack |
|
valve device stack .......................................................................................... | 551-14-12 |
stage |
|
stage (of a series connection) .......................................................................... | 551-15-22 |
state |
|
circuit crest working off-state voltage .............................................................. | 551-16-53 |
circuit non-repetitive peak off-state voltage ..................................................... | 551-16-55 |
circuit off-state interval ................................................................................... | 551-16-52 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
conducting state ............................................................................................. | 551-16-40 |
forward blocking state .................................................................................... | 551-16-41 |
off state .......................................................................................................... | 551-16-41 |
on state .......................................................................................................... | 551-16-40 |
reverse blocking state ..................................................................................... | 551-16-42 |
step |
|
step-down converter ...................................................................................... | 551-12-33 |
step-up converter ........................................................................................... | 551-12-32 |
stiff |
|
current stiff a.c./d.c. converter ........................................................................ | 551-12-04 |
voltage stiff a.c./d.c. converter ........................................................................ | 551-12-03 |
supply(ies) |
|
constant current power supply ........................................................................ | 551-19-05 |
constant voltage or constant current power supply ........................................... | 551-19-06 |
constant voltage power supply ........................................................................ | 551-19-04 |
parallel operation (of stabilized power supplies) .............................................. | 551-19-11 |
stabilized power supply .................................................................................. | 551-19-03 |
switch |
|
electronic AC (power) switch ......................................................................... | 551-13-02 |
electronic DC (power) switch ......................................................................... | 551-13-03 |
electronic (power) switch ............................................................................... | 551-13-01 |
semiconductor switch ..................................................................................... | 551-13-05 |
switched |
|
switched valve device ..................................................................................... | 551-14-08 |
switching |
|
automatic switching off ................................................................................... | 551-18-08 |
automatic switching on .................................................................................... | 551-18-07 |
electronic (power) switching ........................................................................... | 551-11-03 |
symmetrical |
|
symmetrical phase control ............................................................................... | 551-16-24 |
T | |
THD |
|
THD (abbreviation) ........................................................................................ | 551-17-06 |
THF |
|
THF (abbreviation) ........................................................................................ | 551-17-05 |
threshold |
|
threshold voltage (of an electronic valve device) .............................................. | 551-17-26 |
through |
|
conduction through ......................................................................................... | 551-16-64 |
tolerance |
|
tolerance band ............................................................................................... | 551-19-07 |
total |
|
total direct voltage regulation .......................................................................... | 551-17-23 |
total harmonic distortion ................................................................................. | 551-17-06 |
(total) harmonic factor .................................................................................... | 551-17-05 |
transfer |
|
transfer factor (of a d.c. converter) ................................................................. | 551-16-39 |
transformer |
|
interphase transformer .................................................................................... | 551-14-16 |
transition |
|
transition current ............................................................................................. | 551-17-20 |
trigger |
|
trigger advance angle ...................................................................................... | 551-16-34 |
trigger delay angle ........................................................................................... | 551-16-33 |
triggering |
|
triggering ........................................................................................................ | 551-16-61 |
turn-off |
|
turn-off arm .................................................................................................... | 551-15-08 |
two-quadrant |
|
two-quadrant converter .................................................................................. | 551-12-35 |
U | |
uniform |
|
non-uniform connection .................................................................................. | 551-15-18 |
uniform connection ......................................................................................... | 551-15-15 |
V | |
vacuum |
|
high vacuum valve device ................................................................................ | 551-14-10 |
valve |
|
breakdown (of an electronic valve device or an arm) ....................................... | 551-16-66 |
controllable valve device ................................................................................. | 551-14-03 |
electronic valve device .................................................................................... | 551-14-02 |
gas-filled valve device ..................................................................................... | 551-14-11 |
high vacuum valve device ................................................................................ | 551-14-10 |
ionic valve device ........................................................................................... | 551-14-11 |
latching valve device ....................................................................................... | 551-14-07 |
non-controllable valve device ......................................................................... | 551-14-04 |
non-reverse blocking valve device .................................................................. | 551-14-06 |
reverse blocking valve device ......................................................................... | 551-14-05 |
semiconductor valve device ............................................................................ | 551-14-09 |
switched valve device ..................................................................................... | 551-14-08 |
threshold voltage (of an electronic valve device) .............................................. | 551-17-26 |
(valve) arm ..................................................................................................... | 551-15-01 |
valve device assembly .................................................................................... | 551-14-13 |
valve device blocking ..................................................................................... | 551-16-69 |
valve device commutation ............................................................................... | 551-16-16 |
valve device quenching ................................................................................... | 551-16-20 |
valve device stack .......................................................................................... | 551-14-12 |
voltage |
|
a.c. voltage converter ..................................................................................... | 551-12-25 |
circuit crest working off-state voltage .............................................................. | 551-16-53 |
circuit crest working reverse voltage ............................................................... | 551-16-56 |
circuit non-repetitive peak off-state voltage ..................................................... | 551-16-55 |
circuit non-repetitive peak reverse voltage ....................................................... | 551-16-58 |
circuit repetitive peak off-state voltage ............................................................ | 551-16-54 |
circuit repetitive peak reverse voltage ............................................................. | 551-16-57 |
commutating voltage ....................................................................................... | 551-16-02 |
constant voltage to constant current crossover ................................................. | 551-19-08 |
constant voltage or constant current power supply ........................................... | 551-19-06 |
constant voltage power supply ........................................................................ | 551-19-04 |
controlled conventional no-load direct voltage ................................................. | 551-17-18 |
controlled ideal no-load direct voltage ............................................................ | 551-17-16 |
conventional no-load direct voltage ................................................................. | 551-17-17 |
direct voltage regulation .................................................................................. | 551-17-21 |
ideal no-load direct voltage ............................................................................ | 551-17-15 |
indirect voltage link a.c. converter ................................................................... | 551-12-21 |
inductive direct voltage regulation ................................................................... | 551-17-25 |
inherent direct voltage regulation ..................................................................... | 551-17-22 |
quenching voltage ........................................................................................... | 551-16-22 |
real no-load direct voltage .............................................................................. | 551-17-19 |
resistive direct voltage regulation ..................................................................... | 551-17-24 |
ripple voltage (on the DC side) ....................................................................... | 551-17-27 |
stabilized voltage characteristic ....................................................................... | 551-18-05 |
threshold voltage (of an electronic valve device) .............................................. | 551-17-26 |
total direct voltage regulation .......................................................................... | 551-17-23 |
voltage fed inverter ......................................................................................... | 551-12-11 |
voltage stiff a.c./d.c. converter ........................................................................ | 551-12-03 |
way |
|
double-way connection (of a converter) .......................................................... | 551-15-13 |
single-way connection (of a converter) ............................................................ | 551-15-12 |
wheeling |
|
free-wheeling arm .......................................................................................... | 551-15-07 |
width |
|
pulse width modulation control ....................................................................... | 551-16-30 |
working |
|
circuit crest working off-state voltage ............................................................. | 551-16-53 |
circuit crest working reverse voltage ............................................................... | 551-16-56 |
УДК 001.4:621:006.354 | МКС 29.020; 33.020; 01.040.33 | IDT |